Detail Information

Self Life: 2 Years Reading Time: 10-15 Min
Accuracy: 99% Specimen: Saliva
Package: 1 Pcs / Pouch Instrument Classification: Class III
OEM Service: Acceptable Application: Home & Medical Examination

Product Description

Accurate Rapid Antigen Test Kit For Respiratory Disease Coronavirus Saliva Specimen Test

Accurate Rapid Antigen Test Kit For Respiratory Disease Coronavirus Saliva Specimen Test 0

 
 

INTENDED USE

 

The Ag Rapid Test is an in vitro immunochromatographic assay for the qualitativ detection of Influenza antigen in a test device from nasal swab, throat swab or nasal wash/aspirate specimens. It is intended to aid in the rapid differential diagnosis of influenza SARS-CoV-2 viral infections. This test provides only a preliminary test result. Therefore, any reactive specimen with the Ag Rapid Test must be confirmed with alternative testing method(s) and clinical findings. The test is intended for professional and laboratory use.

 

MAINCOMPONENTS

 
Test Device (25): Each foil pouch contains one single-use test device with one membrane strips. The strip contains a test line of monoclonal

Extraction Tube(25): One tube containing 0.5ml extraction solution.

Dropper (25)

Sterile Nasal Swab(25)

 

【STORAGE INSTRUCTIONS

 

1. Store at room temperature (2-30℃ or 35.6-86°F) in a dry place. Avoid direct sunlight;

2. 12 months of shelf life (date of manufacture to expiration date).

 

TESTPROCEDURE
 
Step 1 Bring the test to room temperature (18-26℃) before use.
Step 2 Open the foil pouch, take out the test and lay it on an even surface.
Step 3 Add 5 drops(about 80 µL )of extraction mixture into the each sample well (S).
Step 4 Read and record the results at 15 minutes after addition of samples.
NOTE: Result will be invalid after 20 minutes. After observing and recording the result, dispose of bio-hazardous materials by following the practices of your institution. Discard all the materials in a safe and acceptable manner in compliance with all the federal, state, and local requirements.
Accurate Rapid Antigen Test Kit For Respiratory Disease Coronavirus Saliva Specimen Test 1
 
【EPLANATION OF TEST RESULTS】

1. Negative result: if only quality control line C appears and test line T show no color, it means no Influenza antigen is detected and the test result is negative (as shown in the following figure).

 

Accurate Rapid Antigen Test Kit For Respiratory Disease Coronavirus Saliva Specimen Test 2

2.Positiveresult:If the third strip both quality control line C and T appear, it means the antigen is detected and the test result is the antigen positive (as shown in the following figure)

Accurate Rapid Antigen Test Kit For Respiratory Disease Coronavirus Saliva Specimen Test 3

 
3. Invalid result: if quality control line C can not be observed, regardless of test line, the result would be invalid.(as shown in the following figure) The sample should be tested again.
Accurate Rapid Antigen Test Kit For Respiratory Disease Coronavirus Saliva Specimen Test 4
 

NOTE
1.The intensity of color in the test line (T) may vary depending on the concentration of analyses present in the specimen. Therefore, any shade of color in the test line (T) should be considered positive. Please note that this is a qualitative test only, and cannot determine the concentration of analyses in the specimen.

2.Insufficient specimen volume, incorrect operating procedure or expired tests are the most likely reasons for control band failure.

 

【PERFORMANCE CHARACTERISTICS】

1. Negative reference coincidence rate

Use 10 samples of Ag negative reference to test, the test results should not be positive, the negative coincidence rate should be 10/10;

2. Positive reference coincidence rate

Use 10 samples of Ag positive reference to test, the test result should all be positive, the positive coincidence rate should be 8/10;

3. Sensitivity

Use 3 samples of Ag sensitivity reference to test, L1 should be detected, L2 should be detected or not,L3 should not be detected.

4. Repeatability

Use 1 sample of internal control repeatability reference( J1) to complete the parallel test for 10 tests, the results should be coincident.

5. Cross-reaction and interference reaction

Use positive samples of Rhinovirus, RS virus, Influenza A virus, Influenza B virus, Chlamydia, Mycoplasma and Bacterial Infection to do the tests, the test results should be negative.

6. The Clinical study

The Ag Rapid Test has been evaluated with 155 clinical samples. Both 91 negatives and 64 positives were confirmed by PCR

 

The Ag Test v.s. PCR

Test Method

 

Viral culture results

Total

 

PositiveNegative
The Ag TestPositive52759
Negative128496
Total6491155

[1] Sensitivity = A/(A+ C) ×100%= 81.3%

[2] Specificity = D/(B+ D) ×100%= 92.3%

[3] Crude coincidence rate= (A+D)/(A+B+C+D)×100%= 87.7%

[4] Consistency factor kappa = 0.744

 

【EXPLANATION OF SYMBOLS ON LABEL AND PACKAGE】

 

Accurate Rapid Antigen Test Kit For Respiratory Disease Coronavirus Saliva Specimen Test 5

 
【Company profile】
Lycome International Industry Limited was established in 2020 and is located in Zhongshan City, Guangdong Province, with a registered capital of 10 million yuan. We have our own large-scale production base which covered more than 6 production line,10000 square meters workshop.
Lycome International Industry Limited is a high-tech private enterprise dedicated to the research, development, production, sales and service of medical consumable products. We insist on the aim of "Creation, development and effective communication"Aswell as built the spirit of teamwork with "Human health, concerning on service". We've formed a complete one-stop service systems include R & D, production, sales, logistics, after-sales service.
 

FAQ
 
Q1:Can I have a sample order?
A: Yes, we welcome sample orders to test and check quality. Mixed samples are acceptable.
Q2:What is the lead time?
A:Sample needs 1-3 days, mass production needs 5-10 days.
Q3:Do you have any MOQ limit?
A: The MOQ is according to different products
Q4:How do you ship the goods and how long does it take to arrive?
A: We can ship the good by Air cargo,Express or Sea.It can be delivered in 10 days.
Q5:How to proceed the order if I have logo to print?
A: Firstly, You need give us your logo pictures, and next we will produce a real sample for your confirmation. if mockup is ok,
finally we will go to mass production.
Q6:Do you accept drop shipping?
A: Yes, it’s available.
Q7: Are you manufacturer or trader?
A:We are manufacturer and located in Shenzhen ,we are also a CFDA certificated factory!
Any doubt please contact us freely

You Might Be Into These
Get in touch with us

Enter Your Message

ray_z@consumablemedicalsupplies.com
+8613392649067
13392649067
live:.cid.156f1a39de713476
86-13392649067